Metalworking ·

Semi-synthetic soluble oils are mixed with water at a set ratio, typically between 4 and 8 percent depending on the operation. When concentration drops, the risk of corrosion and bacteria rises; when it is too high, consumption and skin irritation increase.

Measuring with a refractometer

  • Take a clean sample from the tank and place a drop on the refractometer prism
  • Multiply the Brix reading by the product's refractometer factor
  • Compare the result with the target and add concentrate or water as needed

The right mixing order

Always add oil to water, never the other way round. Adding water to oil creates an unstable emulsion. Using pre-mixed fluid for top-ups also keeps concentration steady.

Cleaning the fluid regularly with a chip and oil separation system noticeably extends coolant life.